2000W Pure sine wave inverter
Pure sine wave output(THD<3%)
Output frequency:50/60Hz switch selectable
Input&output fully isolation design
High efficiency 88~94%
Capable of driving inductive & capacitive loads
Tri-Color indicators display input voltage,output load level and failure status
Loading controlled cooling fan
Advanced microprocessor
SC/OV/UV/OT/OL protections.
|
| Technologica l parameter︱ User manual ︱ Product certification ︱ Assembly drawing |
|
SK2000
Model |
SK2000-112 |
SK2000-124 |
SK2000-148 |
SK2000-212 |
SK2000-224 |
SK2000-248 |
Output Power |
2000W |
OutputPower(Max) |
2300W |
Surge Power |
4000W |
Input Voltage |
12VDC |
24VDC |
48VDC |
12VDC |
24VDC |
48VDC |
Output Voltage |
100/110/120VAC+-3% |
220/230/240VAC+-3% |
Frequency |
50/60HZ+/-0.05% |
Output Wave |
Pure sine wave(THD<3%) |
Efficiency |
89% |
92% |
93% |
91% |
94% |
95% |
No Load Current Draw |
2.8A |
1.5A |
0.7A |
2.8A |
1.5A |
0.7A |
DC current draw |
0.50A |
0.30A |
0.16A |
0.50A |
0.25A |
0.12A |
InputVoltageRange |
10.5-15 |
21.0-30 |
42.0-60 |
10.5-15 |
21.0-30 |
42.0-60 |
LED display VoltageLoad |
LED Red/Orange/Green |
LED display failure status |
LED Red |
Automatic Protection |
overload,short circuit,over/under input voltage,reverse polarity(fuse) |
Safety |
UL458 |
EN60950 |
EMC |
FCC Class B |
EN50081-1:1992 |
e-Mark
e13-020866 |
EN50082-1:1992 |
EN55022B:1994 |
EN61000-4-2:1995 |
EN61000-4-3:1996 |
ENV50204:1995 |
Operating Tem. |
-10℃~50℃ |
Storage Temperature |
-30℃to70℃ |
Cooling |
(65℃ run,45℃shut off)Load controlled cooling fan |
Dimensions |
422(L)*208(W)*160(H)mm /16.6(L)*8.18(W)*6.30(H)inch |
Weight |
9.0kgs./19.8Lbs. |
|
| |
|
|